Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-11.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84
Cold Sensitization Occurring in a Worker of a Cold Storage Warehouse
Skip Navigation
Skip to contents

Ann Occup Environ Med : Annals of Occupational and Environmental Medicine

OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > Ann Occup Environ Med > Volume 14(2); 2002 > Article
Case Report Cold Sensitization Occurring in a Worker of a Cold Storage Warehouse
Hyun Sul Lim, Kwan Lee, Jong Min Lee

DOI: https://doi.org/10.35371/kjoem.2002.14.2.204
Published online: June 30, 2002
1Department of Preventive Medicine, College of Medicine, Dongguk University, Korea. wisewine@dongguk.ac.kr
2Department of Rehabilitation Medicine, College of Medicine, Dongguk University, Korea.
  • 42 Views
  • 1 Download
  • 0 Crossref
  • 0 Scopus
prev next

OBJECTIVES
The following is a report on a case of cold sensitization in a worker who served as a forklift truck driver in a cold storage warehouse for 5 years from 1996.
METHODS
We examined the patient's blood chemistry and infrared computerized thermographic measurements. We also reviewed the environmental temperatures at his workplace and interviewed other workers.
RESULTS
The worker was a 32-year-old male who had worked in a cold storage warehouse for 5 years (1996-2000). He complained of headaches, arthralgia, and slight dyspnea after 2 years work serving as a forklift truck driver in a cold storage facility. In the laboratory record of his blood and those of others, the C-reactive protein, rheumatoid facror, anti-nuclear antibody, cryoglobulin and other blood chemistries were all negative except that the anti-streptolysin O titer was reactive and alkaline phosphatase was also increased. The radiologic findings were normal. Using infrared computerized thermographic measurements, the patient's hands were at around 30 degrees C and below in the first infrared image and around 27 degrees C in the third image. Accordingly, he was diagnosed as having cold sensitization, which occurs in persons exposed to cold for long time, especially below freezing point.
CONCLUSIONS
We confirmed that the cold sensitization occurred in this patient as an occupational disease due to an exposure to cold. To prevent cold injury, we must modify work procedures, begin comprehensive medical surveillances, educate workers on risks of cold, and increase workers awareness of safety regulations in the workplace.