Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-11.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84
A Case of Reactive Dye Induced Asthma in an Exposed Worker near a Dye Factory
Skip Navigation
Skip to contents

Ann Occup Environ Med : Annals of Occupational and Environmental Medicine

OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > Ann Occup Environ Med > Volume 14(3); 2002 > Article
Case Report A Case of Reactive Dye Induced Asthma in an Exposed Worker near a Dye Factory
Kyoo Sang Kim, Jung Won Park, Chein Soo Hong, Seong Kyu Kang

DOI: https://doi.org/10.35371/kjoem.2002.14.3.326
Published online: September 30, 2002
1Industrial Safety and Health Research Institute, KOSHA, Korea. kobawoo@kosha.net
2Department of Internal Medicine, Yonsei University College of Medicine, Korea.
  • 53 Views
  • 0 Download
  • 1 Crossref
  • 0 Scopus
prev next

OBJECTIVES
Reactive dye (RD) induced bronchial asthma is a well known form of occupational asthma. We report a case of occupational asthma due to RD in an exposed worker near a dye factory.
METHODS
To evaluate the work-relatedness of bronchial asthma, we examined all possibilities by considering the working environment and performing a personal clinical survey, such as interview on the previous history of allergic diseases, clinical and immunological investigation including skin prick tests, bronchoprovocation tests, and serial peak expiratory flow rates (PEFR).
RESULTS
Occupational asthma of internal origin was excluded by the characteristics of asthma, absence of occupational allergens, and negative PEFR result in the worker's own workplace. However, specific IgE and skin prick tests with reactive dye allergens were all strongly positive. RD challenge test showed maximal 34 % fall of FEV1 at 10 minutes of exposure (PD2 0: 2.11 mg/ml).
CONCLUSIONS
We concluded that this case was an example of bronchial asthma by external occupational allergens. This case suggests that RD induced asthma may also occur in workers and inhabitants who have lived near a reactive dye manufacturing factory.