Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-09.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84
Relationship of Biological Indices of Manganese with Pallidal Index on MRI in Liver Cirrhotics
Skip Navigation
Skip to contents

Ann Occup Environ Med : Annals of Occupational and Environmental Medicine

OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > Ann Occup Environ Med > Volume 16(2); 2004 > Article
Original Article Relationship of Biological Indices of Manganese with Pallidal Index on MRI in Liver Cirrhotics
Younghee Choi, Neung Hwa Park, Jung Woo Shin, Hyo Kyung Kim, Sung Ryul Kim, Tae Heum Jeong, Ji Kang Park, Hun Lee, Cheol In Yoo, Choong Ryeol Lee, Ji Ho Lee, Yangho Kim

DOI: https://doi.org/10.35371/kjoem.2004.16.2.129
Published online: June 30, 2004
1Department of Occupational and Environmental Medicine, Ulsan University Hospital, Korea. yanghokm@nuri.net
2Department of Internal Medicine, Ulsan University Hospital, Korea.
3Department of Neurology, Ulsan University Hospital, Korea.
4Department of Clinical Pathology, Ulsan University Hospital, Korea.
5Department of Family Medicine, Ulsan University Hospital, Korea.
6Department of Radiology, Ulsan University Hospital, Korea.
  • 27 Views
  • 0 Download
  • 0 Crossref
  • 0 Scopus
prev next

OBJECTIVES
The objectives of this study were to clarify which biological manganese exposure indices reflect the pallidal signal intensities in magnetic resonance imaging (MRI) in liver cirrhotics.
METHODS
We examined whole blood, plasma, RBC and urinary manganese concentrations, as well as, brain MRI in 22 cirrhotic patients and 10 healthy controls. From MRI scans we calculated the signal intensity of the globus pallidus using the pallidal index (PI), the ratio of the globus pallidus to subcortical frontal white-matter signal intensity in axial T1-weighted MRI planes multiplied by 100. In addition, we studied the relationships between PI and other measurements.
RESULTS
The high signal intensity in the globus pallidus on T1-weighted MRI was observed in 18 (81.8%) patients. There was a significant correlation between whole blood and RBC manganese concentration, and PI on MRI. According to multiple linear regression, whole blood and RBC manganese concentration reflected PI on MRI better the other indices did.
CONCLUSIONS
Whole blood and RBC manganese concentrations could be useful as biological manganese exposure indices that reflect PI on MRI.