Assessment of Environmental Monitoring Items for Mixed Organic Solvents in Work Place
Skip Navigation
Skip to contents

Ann Occup Environ Med : Annals of Occupational and Environmental Medicine

OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > Ann Occup Environ Med > Volume 6(2); 1994 > Article
Original Article Assessment of Environmental Monitoring Items for Mixed Organic Solvents in Work Place
Soo Hun Cho, Ho Jang Kwon, Mi Na Ha, Sang Hwan Han, Yong Hyeon Yim, Sung Tae Oh

DOI: https://doi.org/10.35371/kjoem.1994.6.2.259
Published online: September 30, 1994
Department of Preventive Medicine, Seoul National University College of Medicine, Korea.
  • 20 Views
  • 0 Download
  • 0 Crossref
  • 0 Scopus
prev next

Ambient air monitoring(environmental monitoring) and biological monitoring of mixed organic solvents exposure have been used in exposure assessment of these compounds in the work environment. Environmental monitoring is more useful when assessing low level exposure to these compounds. The specific objectives of this study were to measure air organic solvent levels in the work environment, to test the agreement of items measured in this study with items which have been reported to the administrative agency, and finally to evaluate the appropriateness of environmental monitoring items. The study subjects were 13 small companies in which less than 300 employees were working and presumably exposed to mixed organic solvents(e.g. automotive repair and painting, 6; textile dyeing, 2; printing, 2; electronics, etc, 3). Personal air samplings were performed by the flow-lite sampling pump(MSA) and the 600mg charcoal tube with air velocity of 100ml/min for qualitative analysis and 2l/min for quantitative analysis. Samples were analysed by gas chromatography/mass spectrometry(Hewlett-Packard 5890/5970). High levels of toluene, n-hexane, and MIBK were detected in most study companies and low levels of ethylbenzene, xylene, n-butylacetate were also detected. When these measured items were compared with those of reported items, only 6 of 13 companies showed relatively good agreement between them. Two companies failed to report items exceeding the limit value. In conclusion, qualitative analysis of ambient air organic solvents seemed to be as important as quantitative analysis of these compounds and a periodic evaluation of monitoring items reported to the administrative agency should be required.