Distribution of Asymmetrical Hearing Loss Among the Workers participated in Noise-specific Health Examination
Skip Navigation
Skip to contents

Ann Occup Environ Med : Annals of Occupational and Environmental Medicine

OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > Ann Occup Environ Med > Volume 11(3); 1999 > Article
Original Article Distribution of Asymmetrical Hearing Loss Among the Workers participated in Noise-specific Health Examination
Youngjun Kwon, Kyungrae Kim, Soo Jin Lee, Jaechul Song

DOI: https://doi.org/10.35371/kjoem.1999.11.3.361
Published online: September 30, 1999
1Department of Occupational Medicine, Hanyang University Medical Center, Korea.
2Department of Otolaryngology, College of Medicine, Hanyang University, Korea.
3Department of Preventive, College of Medicine, Hanyang University, Korea.
  • 60 Views
  • 0 Download
  • 0 Crossref
  • 0 Scopus
prev next

OBJECTIVES
Noise-induced hearing lose(NIHL) is characterized by bilaterally symmetrical hearing loss, but some screening audiometries of employees who were exposed noise showed asymmetry. Therefore, this study was carried out to evaluate distribution of asymmetrical hearing loss and factors influencing asymmetries.
METHODS
Study subjects were 294 male employees who have participated in 1st and 2nd noise-specific health examination.
RESULTS
The interaural threshold difference of 20 dB or more at 4,000 Hz was classified as asymmetry. Among 294 NIHL employees. 19% had left asymmetric hearing loss. 22% had right asymmetric hearing loss. and overall asymmetry were 41%. Prevalence of asymmetry at 4,000 Hz significantly more decreased in middle(80~84 dB (A)) and high-level noise exposure groups(> or =85 dB(A)) than low-level exposure group and significantly increased as greater hearing threshold level in the worse ear. Prevalence of left asymmetry at 4,000 Hz significantly increased as greater hearing threshold level in the worse ear than right asymmetry. The interaural difference was significantly greater in the left asymmetry.
CONCLUSIONS
Noise exposure produced asymmetric hearing loss(interaural asymmetry was 20 dB and more in 41% of case) and left ear was more susceptible to noise demage than right ear.