6 Cases of Hand Arm Vibration Syndrome in Grinding Workers Exposed to Hand-arm Vibration
Skip Navigation
Skip to contents

Ann Occup Environ Med : Annals of Occupational and Environmental Medicine

OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > Ann Occup Environ Med > Volume 12(3); 2000 > Article
Case Report 6 Cases of Hand Arm Vibration Syndrome in Grinding Workers Exposed to Hand-arm Vibration
Shang Hyuk Yim, Rokho Kim, Gil Seung Yang, Jung In Yang, Sang Sup Kim, Hyoung Joon Chun, Si Bog Park

DOI: https://doi.org/10.35371/kjoem.2000.12.3.421
Published online: September 30, 2000
  • 22 Views
  • 0 Download
  • 3 Crossref
  • 0 Scopus
prev next

OBJECTIVES
To confirm the HAVS in workers exposed to hand-arm vibration with using the objective diagnostic methods METHODS: Several tests were used to help substantiate a clinical diagnosis of HAVS. Some other diseases were excluded by a medical interview, hematologic assessment, urinalysis, X-rays. The hand-arm vibration acceleration level of the grinder was evaluated for considering HAVS. Peripheral vascular changes were examined by a cold provocation test. An electromyography was implemented to ascertain the peripheral neural changes.
RESULTS
8 workers with symptoms in hands & fingers, exposed to hand-arm vibration were examined. Some other diseases(primary Raynauds disease, secondary Raynauds disease in not occupational origin) were excluded by a medical interview, hematologic assessment, urinalysis, X-rays. The hand-arm vibration acceleration level of the grinder was 7. 9 m/sec2. The recovery time of a skin temperature followed finger cooling was significantly prolonged in 6 workers with HAVS. The nerve conduction velocity was reduced in 6 workers with HAVS.
CONCLUSIONS
So we report 6 cases of HAVS in grinding workers exposed to hand-arm vibration diagnosed objectively by an exclusion of some other disease, handarm vibration acceleration level, cold provocation test, electromyography.