Warning: mkdir(): Permission denied in /home/virtual/lib/view_data.php on line 81

Warning: fopen(upload/ip_log/ip_log_2024-09.txt): failed to open stream: No such file or directory in /home/virtual/lib/view_data.php on line 83

Warning: fwrite() expects parameter 1 to be resource, boolean given in /home/virtual/lib/view_data.php on line 84
A Case of Hypersensitivity Pneumonitis in a Worker Exposed to Metal Working Fluid
Skip Navigation
Skip to contents

Ann Occup Environ Med : Annals of Occupational and Environmental Medicine

OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > Ann Occup Environ Med > Volume 20(1); 2008 > Article
Case Report A Case of Hypersensitivity Pneumonitis in a Worker Exposed to Metal Working Fluid
Sun Wung Lee, Dong hee Ko, Ku Won Chin, Dong Uk Park, Jung Tak Lee, Yoon Hee Song, Sang Yoon Lee

DOI: https://doi.org/10.35371/kjoem.2008.20.1.37
Published online: March 31, 2008
1Occupational Safety and Health Research Institute, Korea. godong21@hanmail.net
2Korea National Open University, Korea.
3Occupational and Environmental Medicine, Ajou University Medical Center, Korea.
4Department of Occupational & Environmental Medicine, School of Public Health, Seoul National University, Korea.
  • 35 Views
  • 0 Download
  • 4 Crossref
  • 0 Scopus
prev next

INTRODUCTION: There have been no reports of hypersensitivity pneumonitis caused by metal working fluids in Korea, despite their existence in other countries. Here, we report the first such case, along with an assessment of work-relatedness through exposure assessment.
CASE
REPORT: A 64-year old male patient visited the hospital with dyspnea after metal pipe cutting for about a year. He was diagnosed with hypersensitivity pneumonitis from the evidence of specific exposure history, clinical symptoms, and radiologic findings. The air exposure levels of the oil mist, endotoxin, total bacteria and fungus in the work environment was TWA(8-hr) 0.531 mg/m3, 6.33 EU/m3, 100 CFU/m3 and 75 CFU/m3, respectively. The concentrations of the endotoxin, total bacteria and fungus within the metal working fluid was 1.5x10(4) EU/mL, 4.6x10(5) CFU/mL and 1.8x10(5) CFU/mL, respectively.
DISCUSSION
Although the patient did not receive a specific precipitating antibody test, the microbial concentration within the metal working fluid was higher than normal and similar to previous case reports, The oil mist level in the air exceeded the NIOSH REL and ACGIH NIC, and were similar or higher than previous cases. By excluding other causes of hypersensitivity pneumonitis, we concluded that the disease developed from exposure to microbial antigens in the metal working fluid.


Ann Occup Environ Med : Annals of Occupational and Environmental Medicine
Close layer
TOP