Blood Lead Level as a Predictor of Coronary Artery Disease
Skip Navigation
Skip to contents

Ann Occup Environ Med : Annals of Occupational and Environmental Medicine

OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > Ann Occup Environ Med > Volume 21(1); 2009 > Article
Original Article Blood Lead Level as a Predictor of Coronary Artery Disease
Ryoung Jin Park, Seung Hyun Kim, Ji Ung Park, Yang Hyun Kim, Myoung Bo Kim, Won Ju Park, Jai Dong Moon

DOI: https://doi.org/10.35371/kjoem.2009.21.1.38
Published online: March 31, 2009
Department of Occupational and Environmental Medicine, Chonnam National University College of Medicine, Korea. jdmoon@chol.com
  • 19 Views
  • 0 Download
  • 4 Crossref
  • 0 Scopus
prev next

OBJECTIVES
Lead exposure is known to be associated with high blood pressure, hypertension, coronary artery disease, peripheral arterial disease, left ventricular hypertropy, and electrocardiographic abnormalities. We investigated the association between blood lead and coronary artery calcification and stenosis.
METHODS
Between April 2006 and July 2007, 502 adults (345 males and 157 females), who had no history of cardiovascular disease or occupational exposure to lead, were recruited as study subjects. All subjects underwent coronary CT angiography and blood lead measurement.
RESULTS
Blood lead levels were distributed from 0.43 to 11.30 (microgram/dL with a geometric mean blood lead level of 2.98+/-1.5 (microgram/dL. The geometric mean blood lead levels were higher in men than women (3.31+/-1.5 (microgram/dL vs. 2.36+/-1.5 (microgram/dL, P < 0.01). Based on a multivariate analysis, a 1 unit ((microgram/dL) increase in blood lead level was associated with a 1.09 (95% confidence interval, 0.92~1.29) and a 1.01 fold (95% confidence interval, 0.63~1.63) greater risk for coronary artery calcification in men and women, respectively. Similarly, a 1 unit (microgram/dL) increase in blood lead level was associated with a 1.25 (95% confidence interval, 1.03~1.51) and a 1.42 fold (95% confidence interval, 0.73~2.75) greater risk for coronary artery stenosis in men and women, respectively.
CONCLUSIONS
The results suggest that increased blood lead levels are associated with an increased risk of coronary artery stenosis.


Ann Occup Environ Med : Annals of Occupational and Environmental Medicine
Close layer