Skip Navigation
Skip to contents

Ann Occup Environ Med : Annals of Occupational and Environmental Medicine

OPEN ACCESS
SEARCH
Search

Articles

Page Path
HOME > Ann Occup Environ Med > Volume 24(1); 2012 > Article
Original Article Radiotechnologists and Radiation Exposure from PET and PET/CT Systems
Hoon Hee Park, Jeongbae Rhie, Pilkyun Jung, Jong Doo Lee, Jong Uk Won, Jaehoon Roh
Korean Journal of Occupational and Environmental Medicine (대한직업환경의학회지) 2012;24(1):86.
DOI: https://doi.org/10.35371/kjoem.2012.24.1.86
Published online: March 31, 2012
1Department of Radiology, Shingu University, Korea.
2Graduate School of Public Health Yonsei University, Korea.
3Division of Nuclear Medicine, Department of Radiology, Yonsei University Health System, Korea.
4Department of Preventive Medicine-Institute for Occupational Health, College of Medicine, Yonsei University, Korea. jhroh@yuhs.ac
  • 212 Views
  • 1 Download
  • 2 Crossref
  • 0 Scopus
prev next

OBJECTIVES
In this study, radiotechnologists who work performing PET and PET/CT methodologies were analyzed in order to find the cause for the differences in radiation exposure as they applied to general characteristics, work characteristics, knowledge, and exposure recognition or conduct.
METHODS
From April 15th, 2010 to May 14th, 2010, we conducted a retrospective analysis on 80 radiotechnologists using data garnered from their individual general characteristics, work characteristics, knowledge, and exposure recognition or conduct. Their average annual radiation exposure dosages were measured using a thermoluminescence dosimeter. A multiple regression analysis was performed as a statistical tool.
RESULTS
Regarding the general PET and PET/CT characteristics, when the work experience was short, the exposure dose was higher. The factors of age, marriage, work experience in nuclear medicine, PET, PET/CT, and sex were found to have statistically significant effects. The knowledge, recognition, and conduct factors for the radiotechnologists were affected by unsecure radiation exposure at the moment of carrying, unsecure radiation exposure at the moment of injection, the application of protection at the moment of injection, and the use of auto distributor. It was found that, the use of an auto distributor, efforts in reducing the radiation exposure, unsecure exposure when with a patient, and the application of protective procedures at the moment of injection affected the overall factor of radiotechnologists radiation exposure dose.
CONCLUSIONS
We believe that if radiotechnologists would reduce their radiation exposure by using auto distributors, make efforts to reduce the chance of exposure, and be conscious of radiation, they would be able to reduce the radiation exposure dose even during unavoidable circumstances.