Skip Navigation
Skip to contents

Ann Occup Environ Med : Annals of Occupational and Environmental Medicine

OPEN ACCESS
SEARCH
Search

Search

Page Path
HOME > Search
3 "Standards"
Filter
Filter
Article category
Keywords
Publication year
Authors
Special Article
Standards for recognition and approval rate of occupational cerebro-cardiovascular diseases in Korea
Ui-Jin Kim, Won-Jun Choi, Seong-Kyu Kang, Wanhyung Lee, Seunghon Ham, Junhyeong Lee, Yongho Lee, Eunseun Han, Sanghyuk Lee, Yongkyu Kim, Inah Kim
Ann Occup Environ Med 2022;34:e30.   Published online October 25, 2022
DOI: https://doi.org/10.35371/aoem.2022.34.e30
AbstractAbstract AbstractAbstract in Korean PDFSupplementary MaterialPubReaderePub
Background

Although working hours have decreased in Korea, they are still high compared to that of other countries. In Korea, cardiovascular and cerebrovascular diseases (CCVDs) related to overwork in Korea continually occur, and the social burden from overwork is estimated to be high. This study investigated the amendment of regulations affecting the approval rate of occupational CCVDs.

Methods

The change in approval rate of occupational CCVDs and related regulations were investigated using the Act and public notice on the standards for recognition of occupational CCVDs and the yearbooks of the Ministry of Employment and Labor. The CCVD mortality was estimated using data on the number of deaths according to the cause of death, the number of employed people, and resident registration population aged 15–64 years. The cumulative mortality of CCVDs was estimated using the Kaplan-Meier method.

Results

Since the establishment of the standards for recognition in Korea in 1982, the scope of occupational diseases has been expanded to include intracerebral hemorrhage, subarachnoid hemorrhage, cerebral infarction, myocardial infarction, and aortic dissection. In 2013, the concept of working hours was introduced in chronic overwork. The approval rate of occupational CCVDs was 44.7% in 2006, which decreased to 12.9% in 2011. After the improvement of related regulations, the approval rate increased to 41.3% in 2018. From 2000 to 2017, the CCVD mortality of both the unemployed and employed tended to decrease, and their cumulative CCVD mortalities were 549.3 and 319.7 per 100,000 people, respectively.

Conclusions

CCVDs are recognized as occupational diseases in Korea. The amendments to the standards for recognition, the introduction of the Occupational Disease Adjudication Committee, the principle of presumption, and the reduction of working hours have changed the approval rate of occupational CCVDs. A strategic approach is needed to further reduce the incidence of CCVDs.

한국의 직업성 뇌심혈관계 질환에 대한 연구
목적
근로기준법 개정 적용 사업장 확대로 우리나라의 근무시간은 지속적으로 감소 추세에 있으나 타 국가에 비하면 여전히 높은 수준이다. 우리나라의 과로 관련 뇌심혈관계 질환은 지속적으로 나타나고 있으며 과로로 인한 사회적 부담이 클 것으로 추정된다. 이번 연구에서는 우리나라 뇌심혈관계 질환의 업무상 질병 승인율 변화 및 관련된 제도의 변화를 요약하고자 하였다.
방법
뇌심혈관계 질환 업무상 질병 인정기준에 관한 법령 및 고시와 고용노동부 사업연보를 통해 뇌심혈관계 질환 산재 승인율 변화 및 관련 규정을 조사하였다. 국가통계포털의 사망 원인, 취업자 수 및 주민등록인구 자료를 사용하여 우리나라의 뇌심혈관계 질환 사망자수, 사망률을 조사하고 Kaplan-Meier 방법을 통해 누적사망률을 산출하였다.
결과
1982년 우리나라에서 뇌졸중과 급성심장사에 대한 업무상 질병 인정기준이 제정된 이후 수차례 개정을 거쳐 인정 대상 질병 범위가 뇌실질내출혈, 지주막하출혈, 뇌경색, 심근경색증, 해리성대동맥류로 확대되었다. 2013년 만성과로 인정기준에 근무시간 개념이 도입되었다. 뇌심혈관계 질환 업무상 질병 승인율은 2006년 44.7%였다가 2011년 12.9%건까지 감소하였다. 제도적인 개선 후 승인율은 2018년 41.3%까지 증가하였다. 2000년부터 2017년까지 뇌심혈관계 질환 사망률은 미취업자 및 취업자 모두에서 감소하는 경향을 보였으며 이 기간 동안 미취업자 및 취업자의 뇌심혈관계 질환 누적사망률은 각각 10만 명당 549.3명 및 319.7명이었다.
결론
우리나라는 뇌심혈관계 질환을 업무상 질병으로 받아들이고 있다. 뇌심혈관계 질환 업무상 질병 승인율은 업무상 질병 인정기준 개정, 업무상질병판정위원회 제도 도입, 추정의 원칙 도입 및 평균 근무시간 감소 등에 의해서 변동되었다. 뇌심혈관계 질환은 그 경제적 부담이 크고 예방 가능한 질환으로 지속적인 예방 사업 등 발병 예방을 위한 전략적 접근이 필요하다.

Citations

Citations to this article as recorded by  
  • Association between long working hours and the development of suicidal ideation among female workers: An 8-year population-based study using the Korean Longitudinal Survey of Women & Family (2012–2020)
    Seong-Uk Baek, Yu-Min Lee, Jin-Ha Yoon
    Psychiatry Research.2024; 333: 115731.     CrossRef
  • Association between long working hours and diet quality and patterns: A latent profile analysis of a nationally representative sample of Korean workers
    Seong-Uk Baek, Jong-Uk Won, Yu-Min Lee, Jin-Ha Yoon
    Preventive Medicine.2024; 180: 107890.     CrossRef
  • Self-Esteem Trajectories After Occupational Injuries and Diseases and Their Relation to Changes in Subjective Health: Result From the Panel Study of Workers’ Compensation Insurance (PSWCI)
    Seong-Uk Baek, Won-Tae Lee, Min-Seok Kim, Myeong-Hun Lim, Jin-Ha Yoon, Jong-Uk Won
    Journal of Korean Medical Science.2023;[Epub]     CrossRef
  • 82 View
  • 1 Download
  • 3 Web of Science
  • 3 Crossref
Close layer
Original Article
Acoustic Calibration of Clinical Audiometers Used for Special Periodic Health Examination
Kyoo Sang Kim, Yong Lim Won, Soo Young Chung, Seong Kyu Kang
Korean Journal of Occupational and Environmental Medicine 2004;16(4):381-390.   Published online December 31, 2004
DOI: https://doi.org/10.35371/kjoem.2004.16.4.381
AbstractAbstract PDF
OBJECTIVES
Various problems are encountered during audiometric testing. Deviation from reference threshold levels for supra-aural earphones is often a serious problem when hearing levels are measured. This paper reports the acoustic calibration of clinical audiometers used for special periodic health examination.
METHODS
ANSI S3.6-1996 Specification for Audiometers represents our most current and best resource for information regarding audiometers. The acoustic calibration was measured in 211 clinical audiometers and compared with the ANSI S3.6-1996 reference threshold levels for supra-aural earphones.
RESULTS
Among 211 clinical audiometers, 56 (26.5%) exceeded the permitted deviation from reference threshold levels at any test frequency in ANSI S3.6-1996 for left supra-aural earphones, and 54 (25.6%) for right. An exhaustive calibration was required for 16 audiometers (7.6%) in both supra-aural earphones. The absolute difference in dB deviation from reference threshold levels by performed acoustic calibration at least annually were statistically significant at any test frequency (p<.05).
CONCLUSIONS
The results of this study strongly indicate that clinical audiometry is being conducted with pure-tone audiometers having unallowable sound pressure levels deviations for supra-aural earphones. The validity of audiometric hearing thresholds are significantly affected by these deviations from the acoustic calibration levels of audiometers. Therefore audiometer calibration need to be checked functionally daily and acoustically at least annually.

Citations

Citations to this article as recorded by  
  • Development of Linux based Real-Time Spectrum Analyzer for Puretone Audiometer
    Deok-Hun Kang, Bum-Joo Shin, Gye-Rok Jeon, Soo-Geun Wang
    Journal of the Korea Academia-Industrial cooperation Society.2011; 12(6): 2830.     CrossRef
  • 30 View
  • 0 Download
  • 1 Crossref
Close layer
Original Article
Ambient Noise Levels in the Audiometric Test Rooms Used for Special Periodic Health Examination
Kyoo Sang Kim, Yong Hyu Choi, Yong Lim Won, Seong Kyu Kang
Korean Journal of Occupational and Environmental Medicine 2004;16(3):316-328.   Published online September 30, 2004
DOI: https://doi.org/10.35371/kjoem.2004.16.3.316
AbstractAbstract PDF
OBJECTIVES
The ambient noise levels in the test rooms affect the workers's hearing threshold. The present study was designed to assess the ambient noise levels in the test rooms to determine if valid hearing tests, both pure-tone air conduction and bone-conduction, could be performed in these environments.
METHODS
In the present study, third octave band ambient noise sound pressure levels were measured in 124 audiometric test rooms used for clinical audiometry, and the results were compared with the ANSI third octave band maximum permissible ambient noise levels (MPANLs) for each test condition and frequency range.
RESULTS
The ambient noise SPLs were highest in the lower frequencies, and this decreased as the frequency increased. For the "ears covered"condition, about 24.2% of the rooms were in compliance (pass) with the MPANLs for the 125-8000 Hz, 35.5% were in compliance for the 250-8000 Hz range and 55.6% were in compliance for the 500-8000 Hz range. For the "ears not covered"condition, only about 8.1% of the rooms passed for the 125-8000 Hz, 13.7% of the rooms passed for the 250-8000 Hz range and 34.7% of the rooms passed for the 500-8000 Hz range. All 124 rooms met the OSHA MPANLs.
CONCLUSIONS
The results of this study strongly indicate that clinical audiometry is being conducted in test rooms having unacceptable or excessive ambient noise levels.

Citations

Citations to this article as recorded by  
  • Ambient Noise in Candidate Rooms for User-Operated Audiometry
    Christos Sidiras, Jacob Nielsen, Chris Bang Sørensen, Jesper Hvass Schmidt, René Gyldenlund Pedersen, Ellen Raben Pedersen
    Healthcare.2023; 11(6): 889.     CrossRef
  • Achievements, Problems, and Future Direction of the Quality Control Program for Special Periodic Health Examination Agencies in Republic of Korea
    Yong Lim Won, Kyung Sun Ko, Jae Oh Park, Yoon jung Choi, Hyeji Lee, Jung-min Sung, Mi-young Lee
    Safety and Health at Work.2019; 10(1): 125.     CrossRef
  • 24 View
  • 0 Download
  • 2 Crossref
Close layer

Ann Occup Environ Med : Annals of Occupational and Environmental Medicine
Close layer
TOP