Skip Navigation
Skip to contents

Ann Occup Environ Med : Annals of Occupational and Environmental Medicine

OPEN ACCESS
SEARCH
Search

Search

Page Path
HOME > Search
2 "Korean male"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Article
Validation of High Performance Liquid Chromatographic Method with UV Detector for the Determination of Di(2-ethylhexyl)Phthalate in Plasma in some Korean Male Workers
Yun Jung Yang, Soon Chul Myoung, Sae Chul Kim, Yeon Pyo Hong
Korean Journal of Occupational and Environmental Medicine 2005;17(1):70-78.   Published online March 31, 2005
DOI: https://doi.org/10.35371/kjoem.2005.17.1.70
AbstractAbstract PDF
OBJECTIVES
This study was conducted to validate a simple, rapid and sensitive reverse-phase high-performance liquid chromatographic method with UV detector (HPLC-UV) and present the plasma level of di(2-ethylhexyl)phthalate (DEHP) in some Korean male workers.
METHODS
HPLC-UV for quantification of plasma DEHP was validated by the following guideline from the Center for Drug Evaluation and Research (CDER)-calibration/standard curve, precision, accuracy and recovery. Plasma DEHP from 255 healthy Korean male workers aged from 30 to 60 years was analyzed by validated HPLC-UV method.
RESULTS
The calibration curve over the range 0~150 microgram/liter for the plasma DEHP standard solution showed linearity(r2=0.999). The limit of detection (LOD) and limit of quantification (LOQ) of plasma DEHP were 5.22 microgram/liter and 15.81 microgram/liter, respectively. The accuracy and precision for 2.5 microgram/liter of DEHP were acceptable in CDER guideline on the second and third day but not first day, and those for 50 microgram/liter and 150 microgram/liter of DEHP were acceptable on all three days(Ed-confirm this addition). The distribution of plasma DEHP level was skewed to the left and ranged from 0 to 18.9 microgram/liter. The plasma DEHP level was lower than 10 microgram/liter for 98 % of subjects and lower than 5 microgram/liter for 85 %. The geometric mean and standard deviation of plasma DEHP were 0.4 +/- 1.5 microgram/liter.
CONCLUSIONS
The HPLC-UV method for quantification of plasma DEHP was acceptable by CDER guideline. The plasma DEHP of 255 Korean male workers ranged from 0 to 18.9 microgram/liter and the distribution was skewed to the left.

Citations

Citations to this article as recorded by  
  • Assessment of Di (2-ethylhexyl) Phthalate Exposure by Urinary Metabolites as a Function of Sampling Time
    Moon-seo Park, Yun-jung Yang, Yeon-pyo Hong, Sang-yon Kim, Yong-pil Lee
    Journal of Preventive Medicine and Public Health.2010; 43(4): 301.     CrossRef
  • 24 View
  • 0 Download
  • 1 Crossref
Close layer
Original Article
Normal Predictive Values of FVC and FEV1 for Healthy Korean Male Workers
Domyung Paek, Jung Keun Choi, Byung Soon Choi, Kyou Chull Chung
Korean Journal of Occupational and Environmental Medicine 1994;6(2):175-186.   Published online September 30, 1994
DOI: https://doi.org/10.35371/kjoem.1994.6.2.175
AbstractAbstract PDF
Lung Function test results can be influenced by race, socioeconomic status, and physical fitness. The choice of the most appropriate predictive equations should be based upon these considerations as well as age, sex, and body size. About 70% of Korean males smoke, and non-smokers can be a selective group in Korea. In this study, lung function test results of 683 healthy Korean male workers were analyzed to get the predictive equations of Forced Vital Capacity(FVC), Forced Expiratory Volume in 1 second(FEV(1)), and FEV(1)/FVC (FEV(1)%). The age of studied workers ranged from 18to 60, and most of those finished high school or less. Healthy smokers without any respiratory symptoms or disease history were included in the study, while the effect of smoking on the test results were examined in the analysis. FVC, FEV(1), and FEV(1)% were regressed against age, height, weight and smoking status or smoking amount. Age and height explained FVC and FVC(1) most efficiently and the contribution of other variables were not significant. Whereas, smoking was significantly associated with a decrease in FEV(1)% even among healthy un-symptomatic workers. For FEV(1)%, age, height, and smoking amount were significant variables, constituting the most efficient prediction model. The lower limit of normal for percent predicted values was calculated from lower 95 percentile as well as 95% confidence interval. When the results of this study was compared to those from studies of white Caucasians, the predicted FVC and FEV(1) were lower for the given age and height but the differences were less than 10%. The slopes of regression equation for height and age were, however, not significantly different when the social backgrounds of the studied subjects were similar.

Citations

Citations to this article as recorded by  
  • Factors Associated With Obstructive Pattern Spirometry In Shipyard Workers
    Jahyun Kim, Young Wook Kim, Chang Ho Chae, Jun Seok Son, Chan Woo Kim, Jun Ho Lee, Hyung Wook Park, Byung Mann Cho
    Journal of Korean Society of Occupational and Environmental Hygiene.2015; 25(4): 525.     CrossRef
  • Reference Values for the Pulmonary Function of Korean Adults Using the Data of Korea National Health and Nutrition Examination Survey IV (2007-2009)
    Sang-Yong Eom, Heon Kim
    Journal of Korean Medical Science.2013; 28(3): 424.     CrossRef
  • Changes of Pulmonary Disability Grades according to the Spirometry Reference Equations
    Joung Oh Lee, Byung-Soon Choi
    Tuberculosis and Respiratory Diseases.2010; 69(2): 108.     CrossRef
  • 25 View
  • 0 Download
  • 3 Crossref
Close layer

Ann Occup Environ Med : Annals of Occupational and Environmental Medicine
Close layer
TOP