The effect of increasing the illumination on operators’ visual performance in the control-room of a combined cycle power plant
-
Seyyed Abolfazl Zakerian, Saeid Yazdanirad, Seifollah Gharib, Kamal Azam, Asma Zare
-
Ann Occup Environ Med 2018;30:56. Published online August 29, 2018
-
DOI: https://doi.org/10.1186/s40557-018-0267-3
-
-
Abstract
PDFPubReaderePub
- Background
Lighting is one of the environmental factors affecting the performance of the control room operators. Therefore, the aim of this study was to compare the control room operators’ visual performance in two different illumination conditions at a combined cycle power plant through field-work. MethodsSixteen operators in day shift were evaluated with the Freiburg Visual Acuity test (FrACT) software at two lighting systems with different intensities. It includes the first phase with fluorescent illumination system (Power: 40 W, Color Temperature: 4000 Kelvin, Luminous Flux: 2780 Lumen and Model: Pars Shahab) and the second phase with a combined illumination system includes fluorescent and LED (Power: 48 W, Color Temperature: 4000 Kelvin, Luminous Flux: 5400 Lumen and Model: Mazinoor). ResultsBased on the results, visual performance index and visual acuity significantly increased after the intervention (p < 0.001). As to contrast, more lighting significantly reduced the percentage of recognized contrast (p < 0.001) and increased the contrast performance index (p < 0.001). ConclusionsThe results of this study showed that increasing the intensity of light from the values below the allowable limit to the values above the allowable limit would increase the visual indicators in individuals.
-
Citations
Citations to this article as recorded by
- Ambient light intensity affecting ultrasound operator detection of liver lesions in cine-clips
P.Y.C. Lee, A. Mohamed Afif, A. Anthony, M. Goodyear, P. Lombardo Radiography.2024; 30(4): 1151. CrossRef - Randomized trial comparing the effects of a 3D head-up system and microscope eyepiece-assisted simulated vitrectomy with intraocular illumination on the ocular surface of an operator
Xing Ge, Dandan Liu, Fangfang Fan, Tengyu Xu, Zhengpei Zhang, Haiyang Liu, Suyan Li BMC Ophthalmology.2024;[Epub] CrossRef - Validity and reliability of Farsi version of office lighting survey Questionnaire (OLS)
Mohammad Javad Sheikhmozafari, Omran Ahmadi Journal of Occupational Hygiene Engineering.2022; 8(4): 30. CrossRef - The simultaneous effect of ambient temperature and light intensity on performance: A cross-sectional study
Mahdi Malakoutikhah, Hadiseh Rabiei, Asma Zare, Amir Omidvar International Archives of Health Sciences.2021; 8(3): 170. CrossRef - An empirical regression model toward optimized ergonomic conditions for monitoring room operators using RSM
Ehsan Fallahiarezoudar, Mohaddeseh Ahmadipourroudposht, Nor Hasrul Akhmal Ngadiman Facilities
.2021; 39(7/8): 449. CrossRef - Association Between Lighting Level to Subjective Complaints of Visual Fatigue on Operators in the Auto Welder Section
Edza Aria Wikurendra, Muhammad Shafly Rabbani, Globila Nurika The Indonesian Journal Of Occupational Safety and Health.2021; 10(2): 218. CrossRef - Selecting lighting system based on workers’ cognitive performance using fuzzy best–worst method and QUALIFLEX
Asma Zare, Mahdi Malakoutikhah, Moslem Alimohammadlou Cognition, Technology & Work.2020; 22(3): 641. CrossRef
-